Organic Vapor A1 Cartridge
Packaging: Standard 2pcs/pack, bulk carton available. Each pack marked with model, warnings and storage info.
Protection: Adsorbs organic vapors such as benzene, toluene, xylene and solvents. Pair with filter retainer & cotton for gas+particle protection.
Application: Suitable for spray painting, solvent cleaning, chemical handling, oil & gas and manufacturing. Not for IDLH environments.
Manufacture & Certificates
Produced by our own factory
Certifications: EN 140:1998, EN 143:2021, EN 14387:2021, ISO 9001
Service: OEM customization available, sample support
Description
Technical Parameters
Anhui Wankang Protective Products Co., Ltd. is one of the most reliable manufacturers and suppliers of organic vapor a1 cartridge in China, featured by quality products and good price. Please rest assured to wholesale bulk advanced organic vapor a1 cartridge from our factory. Contact us for customized service and pricelist.
Products Specification
|
Parameter |
Details |
|
Model Number |
WK6001CN |
|
Certificate |
EN 14387:2021 |
|
Structure |
Trapezoidal Cartridge With Bayonet Twist Lock |
|
Primary Filter Media |
High-Iodine Granular Activated Carbon (≥1000 mg/g) |
|
Pre-Filter |
KN95 Grade Particle Filter Cotton (WK5N11CN Compatible) |
|
Housing Material |
High-Strength ABS Plastic with Grid Pattern |
|
Connection Type |
Universal Thread / Bayonet Lock |
|
Operating Temperature |
-20°C to +50°C (-4°F to +122°F) |
|
Shelf Life |
2 Years (Unopened, Sealed Packaging) |
|
Package Contents |
2 Cartridges per Individually Sealed Foil Bag |
|
Storage |
Cool, dry area, away from direct sunlight & chemical fumes |
|
Package |
1 pair/pack, 100 packs/CTN, 56*37*60CM |

Product Introduction

Product Introduction
The organic vapor A1 cartridge serves as the core filtering component of gas masks, featuring a trapezoidal column structure and durable plastic shell with alkali-resistant coating on the outer surface to adapt to complex industrial environments and resist daily corrosion. Built-in with professional smoke filter layer and high-precision filter components, the cartridge adopts dual protection mechanisms of physical activated carbon adsorption and chemical neutralization reaction to effectively intercept and decompose harmful toxic gases in the air.
Classified as type A (brown) professional filter cartridge, it is specially developed for filtering various organic gases and vapors, covering benzene, acetone, alcohols, carbon tetrachloride, trichloromethane and other common industrial organic harmful substances. The organic vapor A1 cartridge is a single-function filter cartridge focusing on organic gas protection, with targeted filtration performance and stable protective effect.
Product Usage Instructions
Product Usage Instructions
This organic vapor A1 cartridge is a supporting consumable for respiratory protection equipment and must be used in pairs with a compatible gas mask instead of working independently. The supporting mask can completely isolate external polluted air, fit closely with the user's face, and protect the nose, mouth and facial skin from harmful substances. During operation, polluted air is purified layer by layer through the filter cartridge's internal adsorption and filtration system, removing organic toxic gases and vapors, and the purified safe air is delivered to the human respiratory system to ensure safe breathing in hazardous working environments.
The cartridge features strong compatibility and can be perfectly adapted to WK6200 half-face respirators and WK6800 full-face respirators, meeting the protective needs of different working scenarios and wearing requirements.

Replacement Cycle & Standards
The service life of the organic vapor A1 cartridge is not fixed. Its actual replacement cycle is affected by multiple factors including the type of pollutants, ambient concentration, daily service duration and on-site environmental conditions. In actual industrial use, the saturation state of the organic vapor A1 cartridge can be accurately judged through sensory changes and use conditions, and timely replacement is the key to ensuring protective effect:
1. Odor & Taste Warning: Once the user smells peculiar pollutants or senses obvious irritating taste during operation, the organic vapor A1 cartridge has failed and needs to be replaced immediately.
2. Increased Breathing Resistance: When obvious breathing resistance is felt and inhalation becomes laborious, it indicates that the internal filter material and activated carbon have reached adsorption saturation and lose filtration capacity.
3. Continuous Operation Standard: For long-term continuous industrial operation environments, it is recommended to replace the organic vapor A1 cartridge every 48 hours as a conventional cycle.
4. Long-term Standby Rule: If the organic vapor A1 cartridge is left unused for several days to two weeks after assembly, even if there is no obvious damage or odor, it is necessary to replace it before reuse to avoid residual adsorption failure risks.

Application Scenarios
1. Painting & Coating Industry: Suitable for automobile sheet metal painting, furniture and hardware spraying, baking paint operations, effectively isolating and filtering paint solvents, toluene, xylene and ester solvent vapors.
2. Printing & Adhesive Industry: Applicable to ink printing, glue bonding and circuit board cleaning operations, providing reliable protection against organic solvents such as acetone and ethyl acetate.
3. Coating Workshop Operations: Ideal for daily paint mixing and spray gun cleaning work in coating workshops to avoid inhalation of mixed organic volatile gases.
4. Chemical Industry Operations: Adapt to chemical workshop production and processing work involving ketones, esters, benzene series and other organic chemicals, reducing the risk of inhalation of harmful organic vapors.

FAQ
1.Q: What does the 6001 cartridge protect against?
A: It is designed for organic vapors such as benzene, toluene, xylene and various hydrocarbon solvents. It does not block particulates by itself. Install filter retainer and filter cotton for combined gas and dust protection.
2.Q: Which respirators can the 6001 filter cartridge fit?
A: It works with half-face and full-face respirators with bayonet twist-lock interface. Please confirm the mask connection type before purchase.
3.Q: How long is the service life of the 6001 cartridge?
A: Service life depends on vapor concentration, temperature, humidity and breathing volume. Replace immediately if you smell or taste contaminants, or notice increased breathing resistance.